• Power Regenerative Drive

    Ratings:

    • 3 ~ 200V, 3.5kW to 105kW
    • 3 ~ 400V, 3.5kW to 300kW

    The R1000 is a power regenerative unit with both braking and regenerative functions. The R1000 shows great energy-saving performance in combination with an inverter. The R1000 will dramatically affect applications with large regenerative loads such as cranes and elevators.Because the R1000 does not require a braking resistor unit, it requires less space and enhances braking ability.

    Features

    • Energy Saving Unit which helps in reducing operational charges
    • Increased Braking Torque provides more braking power with continous regenerative operation.
    • Reliable and Long life
    • Preventive Maintenance.
    • Easy support from a PC
    • Global Business Support.

    Applications

    • Crane
    • Elevators & Escalators
    • Centrifugal Seperators
    • Winders
    • Mixers
    • Machine tools

    Applicable Models

    • A1000
    • V1000
    • J1000
    • Varispeed G7
    • L1000A
    • GA700
    • GA500
    • Servo Drives

    Download

  • Enery Saving Unit

    200V Class

    R1000 Model No Preg(kW) IDC(A) IAC(A)
    CIMR-RD2A03P5 3.5 14 10
    CIMR-RD2A0005 5 20 15
    CIMR-RD2A0007 7 27 20
    CIMR-RD2A0010 10 41 30
    CIMR-RD2A0014 14 55 41
    CIMR-RD2A0017 17 68 50
    CIMR-RD2A0020 20 81 60
    CIMR-RD2A0028 28 112 83
    CIMR-RD2A0035 35 138 102
    CIMR-RD2A0053 53 207 153
    CIMR-RD2A0073 73 282 209
    CIMR-RD2A0105 105 413 306

    400V class

    R1000 Model No Preg(kW) IDC(A) IAC(A)
    CIMR-RD4A03P5 3.5 7 5
    CIMR-RD4A0005 5 11 8
    CIMR-RD4A0007 7 15 11
    CIMR-RD4A0010 10 22 16
    CIMR-RD4A0014 14 30 22
    CIMR-RD4A0017 17 36 27
    CIMR-RD4A0020 20 43 32
    CIMR-RD4A0028 28 58 43
    CIMR-RD4A0035 35 73 54
    CIMR-RD4A0043 43 89 66
    CIMR-RD4A0053 53 109 81
    CIMR-RD4A0073 73 149 110
    CIMR-RD4A0105 105 217 161
    CIMR-RD4A0150 150 320 237
    CIMR-RD4A0210 210 440 326
    CIMR-RD4A0300 300 629 466
  • Control Characteristics
    Product R1000
    Type Power Regenerative Unit
    Compatible Inverter Types A1000, V1000, J1000, GA700, GA500, G7, L1000A, Servo Drives &  All conventional Inverters (with a DC Bus),
    Control Method 120° excitation method
    Regenerative
     Torque
    150% 30 s, 100% 25% ED 60 s, 80% continuous
    Input Power Factor 0.9 min. (for rated load)
    Environmental Factors
    Ambient Temperature −10 to +40°C (UL Type1), −10 to +50°C (IP00, IP20)
    Altitude Up to 1000 meters (derating required at altitudes from 1000 to 3000 m)
    Humidity 95% RH or less (no condensation)
    Shock (2A03P5 to 2A0053, 4A03P5 to 4A0073)10 to 20 Hz:9.8 m/s2,20 to 55 Hz :5.9 m/s2
    (2A0073 to 2A0105, 4A0105 to 4A0300)10 to 20 Hz:9.8 m/s2,20 to 55 Hz: 2.0 m/s2
    Area of Use Indoors (Protected from corrosive gases and dust)
    Protection Features 
    Fuse burnout Operation stops if the fuse burns out.
    Momentary Overcurrent
    Protection
    Operation stops for approx. 250% or higher of the rated power supply current.
    Overload Protection 30 s at approx. 150% of rated current.
    Overvoltage Protection 200 V class: Stops when input voltage exceeds approx. 227 Vac, Output:Stops when DC bus voltage exceeds approx. 410 Vdc
    400 V class: Stops when input voltage exceeds approx. 554 Vac, Output :Stops when DC bus voltage exceeds approx. 820 Vdc
    Undervoltage Protection 200 V class: Stops when input voltage falls below approx. 150 Vac, Output: Stops when DC bus voltage falls below approx. 190 Vdc
    400 V class: Stops when input voltage falls below approx. 300 Vac, Output: Stops when DC bus voltage falls below approx. 380 Vdc
    Momentary Power Loss Immediately stops after Momentary Power Loss is detected.
    Heatsink Overheat
    Protection
    Thermistor
    Charge LED Charge LED illuminates when DC bus voltage is more than 50 V.
    Standards Compliance UL508C, IEC/EN61800-5-1, IEC/EN61800-3
    Power Specifications
    Rated input Voltage/Frequency 400V Class:
    Three-phase AC power supply: 380 to 480 Vac 50/60 Hz
    200V Class :
    Three-phase AC power supply: 200 to 240Vac 50/60Hz
    Allowable Voltage
    Fluctuation
    −15% to 10%
    Allowable Frequency
    Fluctuation
    ±2%
    Common Specifications
    Multi Function Digital Inputs 8 Digital Inputs ( NPN or PNP ) 
    Multi Function Digital Outputs 1 Programmable Relay  M1-M2 (AC 250 V, max. 1 A DC 30 V, max. 1 A min. load DC 5 V, 10 mA), 1 fault relay MA-MB-MC(250 Vac, max. 1 A;30 Vdc, max 1 A(min. 5 Vdc, 10 mA)), 2 photcouplers P1,P2 (48 Vdc, max. 50 mA)
    Multi Function Analog Output 2 Multi function Analog outputs FM-AC &  AM-AC (−10 to +10 Vdc ,2 mA)
    Programming Interface Serial port or USB B port in front of VFD
    Serial communication MEMOBUS/Modbus (RTU mode) comm. RS-485, Max. 115.2 kbps
    Optional communication Protocols Mechatrolink,  CC-Link
    Additional Functions Cooling Fan on/off Switch, Removable Terminal Block with Parameter Backup, MEMOBUS/Modbus (RTUmode) Comm. (RS-422/RS-485 max, 115.2 kbps)

     