• Compact V/f Control Drive

    • 200 V :
      >1 Phase : 0.1 to 1.5kW
      >3 Phase: 0.1 to 3.7 kW
    • 400 V:
      >3 Phase: 0.2 to 3.7 kW

    The J1000 meets all automation requirements for compact applications with variable speed operation and energy saving characteristics. A wide range of useful functions upgrade your machine and offer great potentials

    Features

    • Compact – Sleek desing and side by side installation
    • A Breeze to operate – Easy parameterization with quick setup Mode.
    • Environmentally friendly – Complaince with Eus RoHs directive
    • Automatic torque compensation across entire speed range
    • Stall Prevention Functions for stable operation during changes of load or power supply
    • Auto speed search functionality
    • Extensive Braking features

    Main Application’s

    Download

  • Compact V/F Control Drive

    200V Single Phase

    J1000 Model number PND(kW) IND(A) PHD(kW) IHD(A)
    CIMR-JTBA0001BAA 0.2 1.2 0.1 0.8
    CIMR-JTBA0002BAA 0.4 1.9 0.2 1.6
    CIMR-JTBA0003BAA 0.75 3.3 0.4 3
    CIMR-JTBA0006BAA 1.1 6 0.75 5
    CIMR-JTBA0010BAA 2.2 9.6 1.5 8

    200V Three Phase

    J1000 Model number PND(kW) IND(A) PHD(kW) IHD(A)
    CIMR-JT2A0001BAA 0.2 1.2 0.1 0.8
    CIMR-JT2A0002BAA 0.4 1.9 0.2 1.6
    CIMR-JT2A0004BAA 0.75 3.5 0.4 3
    CIMR-JT2A0006BAA 1.1 6 0.75 5
    CIMR-JT2A0010BAA 2.2 9.6 1.5 8
    CIMR-JT2A0012BAA 3 12 2.2 11
    CIMR-JT2A0020BAA 5.5 19.6 3.7 17.5

    400V Three Phase

    J1000 Model number PND(kW) IND(A) PHD(kW) IHD(A)
    CIMR-JT4A0001BAA 0.4 1.2 0.2 1.2
    CIMR-JT4A0002BAA 0.75 2.1 0.4 1.8
    CIMR-JT4A0004BAA 1.5 4.1 0.75 3.4
    CIMR-JT4A0005BAA 2.2 5.4 1.5 4.8
    CIMR-JT4A0007BAA 3 6.9 2.2 5.5
    CIMR-JT4A0009BAA 3.7 8.8 3 7.2
    CIMR-JT4A0011BAA 5.5 11.1 3.7 9.2
  • Control Characteristics
    Product J1000
    Type Versatile Compact V/f Control Drive 
    Rated Output Voltage (dependent on input) Three Ph 200V Class : 200 to 240VAC
    Three Ph 400V Class : 380 to 480VAC
    Single Ph 200V Class : 200 to 240VAC
    Motor Types Induction Motor
    Control Methods V/f Control (V/f)
    Speed Control Range 1:20 to 1:40
    Starting Torque 150% @3Hz for V/f 
    Frequency Range 0 to 400Hz
    Frequency Accuracy Digital reference: within ±0.01% of the max. output frequency (-10 to +50˚C)
    Analog reference: within ±0.1% of the max. output frequency (25 ±10˚C)
    Frequency Setting Resolution Digital reference: 0.01 Hz
    Analog reference: 1/1000 of the maximum frequency
    Output Frequency
    Resolution
    20 bit resolution at maximum output frequency
    Accel/Decel time 0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings)
    Environmental Factors
    Ambient Temperature -10 to +50˚C (open chassis), -10 to +40˚C (enclosure)
    Altitude Up to 1000 meters
    Humidity 95 RH% or less (no condensation)
    Shock 10 to less than 20 Hz (9.8 m/s2) max., 20 to 55 Hz (5.9 m/s2) max.
    Area of Use Indoors
    Protection Features 
    Motor Protection Motor overheat protection based on output current
    Momentary Overcurrent
    Protection
    Drive stops when output current exceeds 200% of Heavy Duty Rating
    Overload Protection Drive stops after 60 s at 150% of rated output current (Heavy Duty Rating)
    Overvoltage Protection 200 V class: Stops when the DC bus voltage is more than approximately 410 V
    400 V class: Stops when the DC bus voltage is more than approximately 820 V (approx. 740 V when the power supply voltage is less than 400 V)
    Undervoltage Protection Thee Phase 200 V class: Stops when the DC bus voltage decreases to less than approximately 190 V Single-phase 200 V class: Stops when DC bus exceeds approx. 160 V
    Three Phase 400 V class: Stops when the DC bus voltage decreases to less than approximately 380 V(approx. 350 V when the power supply voltage is less than 400 V)
    Momentary Power Loss
    Ride-Thru
    Stops when power loss is longer than 15 ms.
    Heatsink Overheat
    Protection
    Thermistor
    Stall Prevention Separate settings allowed during acceleration and during run. Enable/disable only during deceleration
    Ground Fault Protection Protection by electronic circuit
    Charge LED Charge LED illuminates when DC bus voltage is less than 50 V.
    Standards Compliance ・UL508C
    ・EN61800-3
    ・EN61800-5-1
    Power Specifications
    Rated input Voltage/Frequency 400V Class:
    ・Three-phase AC power supply 380 V to 480 V 50/60 Hz
    ・DC power supply 510 V to 680 V
    200V Class :
    ・Single-phase or Three-phase AC power supply 200 V to 240 V 50/60 Hz
    ・DC power supply 270 V to 340 V
    Allowable Voltage
    Fluctuation
    −15% to 10%
    Allowable Frequency
    Fluctuation
    ±5%
    Common Specifications
    Multi Funcction Digital Inputs 5 Digital Inputs ( NPN or PNP ) , 24VDC. 
    Multi Function Digital Outputs 1 Programmable Relay with MA-MB-MC (250 Vac, 10 mA to 1 A;30 Vdc, 10 mA to 1 A) 
    Multi Function Analog Inputs 1 Multi Function Analog input A1 (0 – 10 V (20 kΩ), 4 – 20 mA (250 Ω)/0 – 20 mA (250 Ω))
    Multi Function Analog Output 1 Multi function Analog output AM-AC (0 – 10 V, 2 mA)
    Optional communication Protocols RS232C, RS422/485
    Additional Functions Momentary power loss ride-thru, Speed search, 9-step speed (max), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Cooling fan on/off switch, Slip compensation, Torque compensation, Frequency jump,Upper/lower limits for frequency reference, DC injection braking at start and stop, Overexcitation braking, Fault restart