AC Drive V1000

  • Compact Vector control Drive Ratings:

    • 1 ~ 200V , 0.1kW to 4.0kw
    • 3 ~ 200V , 0.1kW to 18.5kW
    • 3 ~ 400V , 0.2kW to 18.5kW

    V1000 is a general purpose inverter drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the usage of PM motor without feedback

    Features

    • High flux braking for 50% reduction of braking time
    • Quick response on load and speed changes to improves machine performance.
    • Online Auto-Tuning to optimise for improved motor performance at low speed
    • Open Loop Vector Control for PM motor operation.
    • Safe Disable Inputs for Safe Torque OFF

    Application

    Download

    Brochure

  • Compact Vector control Drive

    200V class Single Phase

    V1000 Model number Pn(kw) In(A) Phd(kw) Ihd(A)
    CIMR-VTBA0001BAA 0.2 1.2 0.1 0.8
    CIMR-VTBA0002BAA 0.4 1.9 0.2 1.6
    CIMR-VTBA0003BAA 0.75 3.3 0.4 3.0
    CIMR-VTBA0006BAA 1.1 6.0 0.75 5.0
    CIMR-VTBA0010BAA 2.2 9.6 1.5 8.0
    CIMR-VTBA0012BAA 3 12 2.2 11

    200V class Three Phase

    V1000 Model number Pn(kw) In(A) Phd(kw) Ihd(A)
    CIMR-VT2A0001BAA 0.2 1.2 0.1 0.8
    CIMR-VT2A0002BAA 0.4 1.9 0.2 1.6
    CIMR-VT2A0004BAA 0.75 3.5 0.4 3
    CIMR-VT2A0006BAA 1.1 6 0.75 5
    CIMR-VT2A0010BAA 2.2 8 1.5 8
    CIMR-VT2A0012BAA 3 9.6 2.2 11
    CIMR-VT2A0020BAA 5.5 12 3.7 17.5
    CIMR-VT2A0030FAA 7.5 17.5 5.5 25
    CIMR-VT2A0040FAA 11 19.6 7.5 33
    CIMR-VT2A0056FAA 15 68 11 47
    CIMR-VT2A0069FAA 18.5 80 15 60

    400V class Single Phase

    V1000 Model number Pn(kw) In(A) Phd(kw) Ihd(A)
    CIMR-VT4A0001BAA 0.4 1.2 0.2 1.2
    CIMR-VT4A0002BAA 0.75 2.1 0.4 2.1
    CIMR-VT4A0004BAA 1.5 4.1 0.75 3.4
    CIMR-VT4A0005BAA 2.2 5.4 1.5 4.8
    CIMR-VT4A0007BAA 3 6.9 2.2 5.5
    CIMR-VT4A0009BAA 3.7 8.8 3 7.2
    CIMR-VT4A0011BAA 5.5 11.1 3.7 9.2
    CIMR-VT4A0018FAA 7.5 17.5 5.5 14.8
    CIMR-VT4A0023FAA 11 23 7.5 18
    CIMR-VT4A0031FAA 15 31 11 24
    CIMR-VT4A0038FAA 18.5 38 15 31
  • Product V1000
    Max. Motor Output (kW)
    1~230 VAC, 0.1 – 4.0a
    3~200 VAC, 0.1 – 18.5
    3~400 VAC, 0.2 – 18.5
    Applicable Motor
    Induction Motor (IM)
    Synchronous Motor (PM)
    Control
    V/f Control
    Open Loop Vector (OLV)
    Open Loop Vector (OLV) for PM
    Speed control range
    V/f and V/F with PG 1:40
    OLV 1:100
    CLV and OLV for PM 1:10*3
    Max. Output Freqency 400 Hz
    Fieldbus Interfaces
    RS-232C
    RS-422/485 (Memobus/Modbus)
    MECHATROLINK-I
    MECHATROLINK-II
    Ethernet/IP
    EtherCAT
    Modbus TCP
    PROFINET
    CC-Link
    DeviceNet
    PROFIBUS-DP
    CANopen
    Standards
    CE
    UL/cUL
    RoHS
    UL508C
    EN ISO 13849-1 PLd
    IEC/EN61508 SIL2
    Enclosure IP20, NEMA1, IP66, Finless Type
    Functions
    Speed/Torque Control Switching
    Energy Saving Function
    Double Rating (ND/HD)
    Speed Search
    Slip Compensation
    Torque Compensation
    PID Control (with sleep function)
    DriveWorksEZ (PLC SW)
    Momentary Power Loss Ride-Thru
    Application Parameter Presets
    Preventive Maintenance Functions
    RS-232C Interface
  • Compact Vector control Drive Ratings:

    • 1 ~ 200V , 0.1kW to 4.0kw
    • 3 ~ 200V , 0.1kW to 18.5kW
    • 3 ~ 400V , 0.2kW to 18.5kW

    V1000 solar drive is used solar pump applications .

    • Suitable for BLDC and PM motor
    • Suitable for surface mount and submersible pump for 3 Phase 200Volts/400volts induction motor
    • wide range capacity from 0.1kw to 18.5kw
    • All day run stop restart mode management
    • Diagnostics and self protection features.
    • Protection against dry run of pump
    • Simple and faster installation and commissioning.
      V1000 Solar Technical Electrical specification
    Pump inverter type V/F control with derived MPPT Technology
    Dual supply ( Grid/ Solar) Change over Available
    input DC voltage ( VOC) 400volts DC for 200volts Class and 800volts class for 400 volts drive
    input DC voltage ( Vmp) 280 VDC tp 310 V Dc /510 V dc to 620 V DC
    Input DC cuttent and power As per motor capacity
    Min frequency 0hz selectable setting range
    Max frequency 120Hz
    Shock 10 to less than 20 Hz (9.8m/s2) max
    output Ac voltage 3 phase 190-240v (-15%.+10%)/380-480V/(-15%,+10%)
    Output Ac voltage As per chart above
    Motor frequency 0-60Hz
    Motor control technology V/f Control
    MPPT voltage 230V to 360 V for 200 volts

    460V to 620 V for 400 volts

    Over load capacity 120% for ND
    under voltage 125V DC for 200 volts Class/ 250 for 400 volts Class
    protection Dry run , short circuit, Open Phase in input & output side, High Voltage, Low voltage and over load , earthing, recerse polarity.
    Ambient temp -10deg to 50 deg
    Relative humidity Max 95% relative humanity

    Download

    Solar Catalogue

Service Quick